Alphatech Fermax PBX EXP Przewodnik Instalacji Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 42
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
Parameter Value Meaning Basic
52 d
max. call time
2
d max. time, for which the guard is hanging up, this
time can be extended during call by sign choice from
telephone (* or #). Time setting is per table.
List of related parameters: 42 8# 85
Parameter Value Meaning Basic
53 w
time among button presses
2
w max. time [sec] among button presses [range 1-9]
normal buttons
- switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
- dialing – if the button, we are pressing, is the first password number
for switch closing, so the choice is delayed by this w time.
keyboard
- switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
- dialing
- dialing the same as of phone, if time after the last pressed button
is bigger than w time, then the dialing starts. If the number is
incomplete, it is necessary to hang up (X button) and the dialing
will be repeated.
- dialing from memory, if time following the first pressed button is
longer than w time, then the entry of memory number has to be
repeated.
List of related parameters: 1 2 32 33 34 47 48 49 8# 85
Parameter Value Meaning Basic
54 z
time of hanging up when dialing repeated
2
z – time [sec] for which the guard will hang up, before repeated dialing
(button pressing during call or dialing, busy tone detection) [range 1-5]
List of related parameters: 8# 85
time
[min]
choice
0,5 0
1 - 9 1 - 9
15 *
30 #
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 41 42

Komentarze do niniejszej Instrukcji

Brak uwag